Abstract
The uniform magnetic field is widely used in sensors and other laboratory devices. The four-coil configuration has the advantage of open space and good uniformity. Traditional schemes include Lee-Whiting, Tetracoil, Braunbeck, etc. The first two schemes have rounding errors of coil turns. The Braunbeck configuration avoids rounding errors, but the structure is solidified and cannot meet the requirements of flexible sensors. In this study, we derive a general constraint equation that fits various four-coil configurations and show that the constraint parameter uniquely defines the configuration. Moreover, we develop a simple optimization approach that allows building the optimized configuration that lacks rounding errors of coil turns. We analyzed system performance for different coil cross sections and configurations. The comparison of the original Lee-Whiting and optimized coils revealed that the normalized maximum radius Rmax increased by 7.67%. Finally, the increase in cross-section resulted in performance that was principally different from classical models. The proposed approach makes both scientific and educational contributions for future studies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Electrical Engineering & Education
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.