Abstract
The purpose of this article is to demonstrate a novel technique using modified continuous blanket suture (MCBS) to fix the amniotic membrane (AM) in different severe ocular surface disease lesions. The MCBS techniques were used to fix the AMs of 5 representative patients with different ocular surface lesions related to severe ocular surface diseases. In all cases, stable adherence of the AM was maintained until the epithelialization of the ocular surface was completed. No early detachment, dissolution, or dislocation of the AM patch was observed. During follow-up, all patients acquired a smooth and acceptable ocular surface without any persistent epithelial defect, infection, or ulceration. The MCBS method achieved good AM fixation on the ocular surface in cases of severe ocular surface lesions and could prevent the early detachment of the AM and promote the epithelialization of the ocular surface.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.