Abstract
During the period of 2018-2020, we first combined reported low-pass whole genome sequencing and NGS-based STR tests for miscarriage samples analysis. Compared with G-banding karyotyping, the system increased the detection rate of chromosomal abnormalities in miscarriage samples to 56.4% in 500 unexplained recurrent spontaneous abortions. In this study, a total of 386 STR loci were developed on twenty-two autosomes and two sex chromosomes (X and Y chromosomes), which can help to distinguish triploidy, uniparental diploidy and maternal cell contamination and can trace the parental origin of erroneous chromosomes. It is not possible to accomplish this with existing methods of detection in miscarriage samples. Among the tested aneuploid errors, the most frequently detected error was trisomy (33.4% in total and 59.9% in the error chromosome group). In the trisomy samples, 94.7% extra chromosomes were of maternal origin and 5.31% were of paternal origin. This novel system improves the genetic analysis method of miscarriage samples and provides more reference information for clinical pregnancy guidance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.