Abstract
The purpose of this study was to improve the sensitivity and accuracy of the quantitative analysis of polymorphic mixtures. Calibration curve reliability has been improved through the advancement of standard mixture preparation techniques whereby samples at scales of several grams are homogeneously and accurately prepared without decrease in crystallinity. Crystalline powders are first micronized to anisotropic, nearly equal-sized (<10 μm) particles of almost random orientation in an air jet mill. These powders are then mixed in a vibration mill that includes rubber balls as mixing media. Using this technique, α and γ forms of indomethacin (IMC) were prepared in various proportions from 0.5% to 50% α content and subjected to X-ray powder diffraction analysis. The validation data showed that these precisely prepared standard mixtures resulted in superior analytical sensitivity and accuracy compared to those prepared by agate mortar. © 2005 Wiley-Liss, Inc. and the American Pharmacists Association
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.