The MindView European Project pursues the development of a high efficiency and high resolution brain dedicated PET detector, simultaneously working with a Magnetic Resonance Imaging (MRI) system. Since the PET scanner is based on a small diameter ring and on thick monolithic scintillation crystals to assess high efficiency, the parallax error related to off-center positron annihilation is a critical issue. The Depth of Interaction (DoI) discrimination can reduce the blurring due to this phenomenon. In this work, we propose a novel DoI estimator, based on the ratio of the integral of scintillation light distribution to its maximum (named N/I). In a preliminary way, by means of Monte Carlo simulation, we have validated the correlation between this parameter and the DoI. Furthermore, we have experimentally tested the capability of such DoI estimator on a monolithic 20 mm-thick LYSO crystal optically coupled to a 12x12 silicon photomultipliers (SiPMs) array. Thanks to the proposed method, it is possible to select interaction events coming from different depths of the crystal. The DoI discrimination capability has been confirmed by using a collimated slanted pencil-beam: the proposed estimator allows to produce different images coming from events belonging to different depths of the crystal. From the experimental results a DoI discrimination resolution ranging from 4 mm to 6 mm has been obtained. The proposed method is expected to reduce the parallax error and, consequently, the width of lines of response coming from off- center positron annihilation of about 70% respect to the method without DoI discrimination.

Highlights

  • The MindView European Project pursues the development of a high efficiency and high resolution brain dedicated PET detector, simultaneously working with a Magnetic Resonance Imaging (MRI) system

  • Since the PET scanner is based on a small diameter ring and on thick monolithic scintillation crystals to assess high efficiency, the parallax error related to off-center positron annihilation is a critical issue

  • We propose a novel Depth of Interaction (DoI) estimator, based on the ratio of the integral of scintillation light distribution to its maximum

Read more

Summary

Introduction

The MindView European Project pursues the development of a high efficiency and high resolution brain dedicated PET detector, simultaneously working with a Magnetic Resonance Imaging (MRI) system. A novel method for g photons depth of interaction discrimination on monolithic LYSO crystals for brain PET/MRI Roberto Pani1, Marco Bettiol1*, Enrico Preziosi2, Christian Borrazzo3, Rosanna Pellegrini1, Antonio Gonzalez4, Pablo Conde4, Maria Nerina Cinti1, Andrea Fabbri3, Elisabetta Di Castro5, Stan Majewski6

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.