Abstract

A new gadolinium(III) selective electrode has been developed from poly vinyl chloride (PVC) matrix membrane which is based on synthesized neutral carrier [L1] 2-(2-aminothiazol-4-yl)phenol and [L2] 2-(4-phenyl-1,3-thiazol-2-yliminomethyl)phenol as ionophores. The membrane having a composition of ionophore (L2):PVC:plasticizer (acetophenone):additive (sodium tetraphenylborate) in the ratio of 5:33:60:2 exhibited calibration performance over a wide range of concentration of gadolinium (9.38×10−7 to 1.0×10−2 M) and exhibited a Nernst slope of 19.5±0.5mV per decade of Gd(III) activity. It exhibited a quick response time of 8s and its potential response was independent of pH across the pH range of 3.5–8.5. The membrane can be used with a good reproducibility over a period of 3 months. Membrane sensor was used as a indicator electrode for determination of end point in potentiometric titration of Gd (III) ion with EDTA. The proposed membrane electrodes were successfully applied for the determination of the concentration of gadolinium (III) ion in a mineral sample.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.