Abstract

In this work, the problems of references used for oil pollution measurement by UVF method were discussed. The main problem of this method is that the origin of the reference for pollutant oil is unknown. The proposed solution for this problem was based on sea water sample which was taken from contaminated area, extracted by DCM, the organic phase was distilled, its calibration curve was plotted with this residue oil and measurement was made on its equation. The oil pollution results for the sea water of K 0 station by using this equation for 2013 was 15.21 mg/L and for 2014 15.25 mg/L. for the same samples determination of oil pollution by using crude oil references varies between 0.11 and 1.15 various crude oils and using chrysene reference 0.11-0.19 mg/L. These results show that pollution level varied depending on references used. The proposed method more realistically determines the oil pollution level. The proposed technique is the first for oil pollution measurement by UVF.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.