Abstract
Structural integrity assessment of steam generator tubes(SGT) is important for the safety operation of pressurized water reactor. In this work, a repair criterion for Inconel690 SGT with fretting flaw was proposed. Firstly, experiments were conducted to address material strength, eddy current examination and bursting pressure of defected SGT. Then, a numerical method was proposed to predict bursting pressure. At last, all factors were concluded in a simplified statistical method of structural integrity assessment. For anti-vibration bar fretting, Condition Monitoring criterion, Operational Assessment criterion as well as the repair criterion for different inspection interval were proposed. The present criterion can provide reference for the inspection interval considering long-term temporary shutdown or standby.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.