Abstract

Nuclear power plants are no longer immune to cycling operation. While certain nuclear power plants in Europe have been performing load following operation, this type of operation has largely been avoided in the United States. Due to increasing contribution of nuclear generation in the mix, European operators were forced to make modifications to increase the maneuverability of their nuclear generation assets. However, in the United States, nuclear generation is still a relatively smaller contributor (19%), but with rapid increase in renewable generation, some nuclear plans are being asked to operate at reduced power and cycle to lower power levels. These shutdowns are typically of a short-term duration on a weekend or in periods of high renewable megawatt generation. With most future renewable integration studies advocating for increased flexibility on the grid, nuclear generation maneuverability will allow system operators with another resource to mitigate and reduce system costs. This paper presents the results of a detailed study of a 1,150 MW boiling water reactor (BWR) nuclear plant when cycled to low loads. The authors present the relative damage of cycling to various reduced power levels 80% to 15% power levels compared to a cold startup and shutdown of a nuclear plant. An assessment was made of the systems that had fatigue damage and costs. We also discuss some of the limitations of cycling that a nuclear plant has and present and discuss recommendations to reduce damage and costs.