Abstract

In order to study the applicability of EMAR (electromagnetic acoustic resonance) method to non-destructive hydrogen level assessment in fuel spacer bands at pool side, an ultrasonic transmitter and receiver together with an EMAT (electromagnetic transducer) were used. Unirradiated Zircaloy-2 thin plates were hydrogen charged for the measurements. An irradiated fuel cladding tube was also used to examine the detection sensitivity of the resonance spectrum of the irradiated material. The following results were obtained. Acoustic anisotropy Δf, defined by using two resonance frequencies for shear waves with different polarization, was adopted as a parameter to express the ultrasonic resonance property. A hydrogen concentration dependence of Δf was observed in the range up to 1,200 ppm. Specimen thickness and oxide thickness were found to have negligible effect, on Δf, and liftoff of the sensor up to 1mm did not affect the Δf value. The acoustic anisotropy proposed in this paper was not sensitive to any of specimen dimension, surface condition, or sensor liftoff.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call