Abstract
The cell array stress test (CAST) is a very simple tool to study one of the main issues of Non Volatile Memory reliability: data retention. However, it is not possible to easily quantify and localise the retention-failed cells of a CAST. Thus, a new experimental technique to localize and to quantify retention-failed EEPROM cells into a CAST is presented in this paper. This new technique is based on light emission microscopy; the aim is to observe light emission coming from cells and to localize their position with accuracy on CAST area. It is a visual and non destructive method which validity has been shown on cycled cells after a retention test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.