Abstract

The objective of this study was to propose a new method for facilitating needle-beam alignment ultrasound-guided in-plane catheterization of the subclavian vein (SCV). Three hundred patients were recruited, and ultrasound examination of the SCV was performed. Then, the patients were divided into two groups and SCV catheterization was performed: ultrasound-guided catheterization with the aiming method (group A) and ultrasound-guided catheterization with needle guide (group NG). The success rate, insertion time, number of skin breaks, number of needle redirections, needle visibility and rate of mechanical complications were documented and compared for each procedure. To depict the optimum long-axis view of the SCV, there was a 30° ± 7.3° angle (rotation) between the long axis of the ultrasound probe and the clavicle, while there was a 39° ± 7.4° angle (tilt) between the ultrasound beam plane and the right chest wall. The aiming method was associated with fewer skin breaks [(mean (IQR): 1 (1–1) times vs 1 (1–2) times, P = 0.009], a shorter time to cannulation [(mean (IQR): 39 (32–48.5) s vs 48 (44–54.8) s, P = 0.000] and more needle redirections [(mean (IQR): 0 (0–1) vs 0 (0–0), P = 0.000]. There were no differences between group A and group NG in the overall success rate, first puncture success rate, needle visibility or mechanical complication rate. In conclusion, during ultrasound-guided in-plane catheterization of the SCV, the aiming method provides comparable needle-beam alignment with a lower cannulation time than the needle guide technique.

Highlights

  • The objective of this study was to propose a new method for facilitating needle-beam alignment ultrasound-guided in-plane catheterization of the subclavian vein (SCV)

  • We proposed a new aiming method that may facilitate the alignment of the needle with the ultrasound beam, and we found that the aiming method provided comparable needle-beam alignment with a shorter cannulation time than the needle guide technique during ultrasound-guided in-plane catheterization of the SCV

  • Identifying the anatomy of the insertion site and the location of the SCV are key to successful catheterization

Read more

Summary

Introduction

The objective of this study was to propose a new method for facilitating needle-beam alignment ultrasound-guided in-plane catheterization of the subclavian vein (SCV). The success rate, insertion time, number of skin breaks, number of needle redirections, needle visibility and rate of mechanical complications were documented and compared for each procedure. During ultrasound-guided in-plane catheterization of the SCV, the aiming method provides comparable needle-beam alignment with a lower cannulation time than the needle guide technique. We introduced a new aiming method (freehand) to facilitate needle-beam alignment, since it is similar to sight alignment in shooting sports. We hypothesized that this aiming method has comparable alignment performance with the needle guide technique

Objectives
Methods
Results
Conclusion