Abstract

AbstractA new method for determining the efficiency of columns with sieve, sieve‐valve, valve, bubble cap and tunnel trays is introduced, taking into consideration entrainment, weeping and mixing of liquid on the tray. The presented calculation concept is valid for any stripping factors and any quality of liquid mixing on the tray. A comparison of the new calculation concept with experimental data from literature resulted in an average relative deviation of approx. 8% between the sieve tray efficiencies. The comparison of calculated values with experimental data for sieve‐valve, valve and tunnel trays also produced a satisfactory agreement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.