Abstract
A new Doppler method was developed to evaluate the instantaneous cross-sectional velocity profile variability in the left ventricular outlet tract in patients with atrial fibrillation. Blood flow velocities acquired at a high frame rate (>90 frames/s) from a single heart cycle were used to display the velocity profile. In 9 patients, 2 heart cycles with different R-R interval lengths were recorded in color flow mode in a transthoracic apical 5-chamber and long-axis view. Raw digital ultrasound data were analyzed with an external personal computer. The data indicated a variable skew in the profiles with the highest velocities and velocity-time integral (VTI) most often located in the center and toward the septum. The maximum VTI overestimated the mean VTI by approximately 40%. No significant difference existed between the two heartbeats. Thus the VTI can be averaged from heartbeats of different R-R lengths in atrial fibrillation.