Abstract

In this paper, the different temperature dependencies of hysteresis and eddy current losses of non-oriented Si-steel laminations are investigated. The measured iron loss results show that both the hysteresis and eddy current losses vary linearly with temperature between 40 °C to 100 °C, a typical temperature range of electrical machines. Varying rates of hysteresis and eddy current losses with the temperature are different and fluctuate with flux density and frequency. Based on this, an improved iron loss model which can consider temperature dependencies of hysteresis and eddy current losses separately is developed. Based on the improved iron loss model, the temperature influence on the iron loss can be fully considered by measuring iron losses at only two different temperatures. The investigation is experimentally validated by both the tests based on a ring specimen and an electrical machine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.