A new correlation used to account for the inundation effect on the prediction of heat transfer between steam vapor and cooling water in tube-and-shell condensers is proposed in this work. The proposed correlation is validated by comparing the predicted results with the experimental data of a steam surface condenser. A modified k–ϵ turbulence model for gas–liquid two-phase flows with distributed flow resistance is used in the numerical simulation. The predicted results using the proposed correlation agree better with the experimental data than those obtained using the existing correlations for inundation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.