Abstract

A new method of depositing copper on alumina substrates is described. This results in less attenuation and better adhesion than that obtained by the prior method. The measured attenuation of microstriplines made by conventional vacuum evaporation of chromegold and by electroless copper deposition methods is compared in the range of 2-10 GHz. It is found that classical chrome-gold metallization gives higher attenuation. The experimental data for this new method are in good agreement with the theoretically predicted values. The superiority of the new method over the prior methods is discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.