Abstract
A new biomimic bulk acoustic wave (BAW) sensor with a molecularly imprinted polymer (MIP) coating has been designed and applied to the determination of phenacetin in human serum and urine. The MIP was prepared using phenacetin as the imprinted molecule and methacrylic acid as the functional monomer. The sensor showed high selectivity and sensitivity in aqueous system. A linear calibration response curve between 5.0×10 −8 M and 5.0×10 −4 M was obtained and the detection limit was 5.0×10 −9 M. The coating of the sensor was stable and can be reused for many times. In the determination of real samples, satisfactory results were achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.