Abstract
AbstractA simple system of packers and plastic standpipes has been used for sampling water and monitoring piezometric levels at four to six selected points in 2.98 inches (76mm) bedrock boreholes for up to five years. The relatively inexpensive packers held a required inflation pressure for at least four months and could be removed from the borehole when desired. The approach used is adaptable for other purposes and has been used for borehole dilution tests and vertical tracer tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.