Abstract
A kind of photonic crystal (PC) micro-cavity sensor based on magnetic fluid (MF) filling is designed with simulation model. Generally, many sensors’ designs are based on a universal temperature in the whole structure. However, strong photothermal effect in high Q micro-cavities will lead to different temperatures between cavities and environment inevitably. In many theoretical PC sensor designs, researchers neglected the different temperature between environment and cavities. This simple hypothesis will probably lead to failure of sensor design and get wrong temperature. Moreover, few theoretical or experimental works have been done to study optical cavity’s heating process and temperature. We propose that researchers should take seriously about this point. Here, the designed cascaded micro-cavity structure has three spectral lines and a reversible sensitivity matrix, which can simultaneously detect magnetic field, ambient temperature and MF micro-cavity temperature. It can solve the magnetic field and temperature cross-sensitivity problem, and further, distinguish the different temperatures of environment and magnetic fluid cavities. The influence of hole radius and slab thickness on the depth and Q value of the resonant spectral line are also studied. Responses of three dips to magnetic field, ambient temperature and MF micro-cavity temperature are simulated, respectively, where dip 1 belongs to MF cavity 1, dip 2 and dip 3 belong to MF cavity 2. The obtained magnetic field sensitivities are 2.89 pm/Oe, 4.57 pm/Oe, and 5.14 pm/Oe, respectively; the ambient temperature sensitivities are 65.51 pm/K, 50.94 pm/K, and 58.98 pm/K, respectively; and the MF micro-cavity temperature sensitivities are −14.41 pm/K, −17.06 pm/K, and −18.81 pm/K, respectively.
Highlights
Magnetic fluid (MF) is a kind of special functional material, which is formed by magnetic particles wrapped with surfactant evenly and distributed in carrier fluid [1]
A kind of photonic crystal (PC) micro-cavity sensor based on magnetic fluid (MF) filling is designed with simulation model
We propose that researchers should take seriously about this point
Summary
Magnetic fluid (MF) is a kind of special functional material, which is formed by magnetic particles wrapped with surfactant evenly and distributed in carrier fluid [1]. It has the properties of magnetic materials and fluid. By integrating waveguide and micro-cavity into a PC slab through introducing defects, various functions can be realized, such as slow light [7], filters [8], optical switches [9], logic gates [10], mode converters [11], and chiral light [12]. Many researchers are devoted to design various PC slab sensors [13]-[18]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.