Abstract

Ultrasonic-guided waves (UGWs) in defective pipes are subject to severe coherent noise caused by imperfect detection conditions, mode conversion, and intrinsic characteristics (dispersion and multiple modes), inducing the limited performance of anomaly imaging. To achieve the high resolution and accuracy of anomaly imaging, a multi-strategy hybrid sparse reconstruction (MHSR) method based on spatial-temporal sparse wavenumber analysis (ST-SWA) is proposed. MHSR leverages the capability of ST-SWA to extract the wavenumber dispersion curves, thereby providing a more refined and precise search space for MHSR. Furthermore, it mitigates the impact of coherent noise by conducting dispersion compensation on the reconstructed signal. The sparse compensated signals through MHSR are employed for sparse reconstruction imaging. To validate the efficacy of the proposed method, UGW testing is performed on the defective steel pipe, and the results demonstrate the significant enhancement of anomaly imaging in defect resolution and positioning accuracy. The lowest estimated errors for axial and circumferential defect positions are 10 mm and 4 mm, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.