Abstract

The corrosion of ductile cast iron in water containing different amounts of chloride ions was investigated under both static and dynamic conditions. Corrosion/time relationships were established for exposure times of up to 30 days. Post-corrosion investigations were performed, employing Mossbauer spectroscopy, optical microscopy and electrochemical techniques. It was found that the nature of the surface corrosion product formed under static conditions differed morphologically and chemically from that formed under dynamic conditions. The latter was a hard layer consisting of a mixture of γ- and β-FeOOH (situated on an underlying cementite layer), whereas the static tests resulted in a soft, spongy corrosion product, identified as β-FeOOH.