This paper proposed a novel approach to calculate the iron loss under DC bias condition using modified Jiles-Atherton (JA) model. The influence of DC bias on the JA model is analyzed. The parameters in the JA model are extracted from BH loops without DC bias but they are applicable for the one under DC bias condition. Thus the modified JA model is practically convenient for iron loss prediction. Moreover, the parameter identification is fast. In addition, the influence of different magnetic induction levels and frequency is incorporated in the model. An accurate measurement system is established to measure the BH loops and iron loss. The tested results are demonstrated and compared with the predicted iron loss to verify the modified JA model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.