Abstract

Guided wave based techniques are among the promising techniques for structural health monitoring due to their ability to detect damage with high precision, ability to scan large area and low power consumption. However, practical implementation of these techniques to structures with relatively complex geometries such as stiffened plates demand further research due to several challenges. Some of such challenges include the presence of stiffeners and edges in close vicinity causing multiple reflections of waves, possibility of multiple damages and lack of baseline data. To address all these issues, a modified hyperbola based approach using mode converted signal and a data based matching scheme has been proposed in this paper. A stiffened plate is taken as the example structure. Corrosion like defects have been considered as the damages. Each panel of the stiffened plate has been scanned separately through phased array actuation. The effectiveness and robustness of the proposed approach have been shown through a case study using 3D finite element simulation data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.