Abstract

AbstractThis work presents a method to obtain the one‐exponential model parameters of a series–parallel association of photovoltaic (PV) devices. From the linear expressions of the I–V characteristic in short‐circuit and open‐circuit zones, simple equations for association model parameters are obtained based on cell parameters. In order to validate the model, measurements have been performed in the 33 cells of a conventional PV module previously modified to have access to its cells, either individually or associated. Series and parallel proposed models have been applied to measurements, supposing all module cells are connected either in series or in parallel. Good approximations have been found in both cases. The method here proposed supplies a useful formulation that can be used in simulation programmes and array calculations. Copyright © 2005 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.