Abstract

The potential function for a point electrode in the vicinity of a vertical fault or dike may be expressed as an infinite integral involving Bessel functions. Beginning with such an expression, two methods are presented for the direct analysis of resistivity data measured both normal and parallel to dikes or faults. The first method is based on the asymptotic expansion of the Hankel transform of the field data and is suitable for surveys done parallel to the strike of the dike or fault. The second method is based on a successive approximation technique which starts from an initial approximate solution and iterates until a solution with prescribed accuracy is found. Both methods are suitable for programming on a digital computer and some illustrative numerical results are presented. These examples show the limitations of the methods. In addition, the application of resistivity data to the interpretation of induced‐polarization data is pointed out.