Abstract

Objective To compare the registration errors of single photon emission computed tomography (SPECT) and CT images using a visual method and the methods of different numbers and combinations of the external markers,and to explore an accurate,reproducible and simple registration method of CT-SPECT lung perfusion images. Methods Two patients with lung cancer underwent thoracic CT scans and SPECT lung perfusion scans. The 9 external markers were fixed on the thoracic region before CT scans and SPECT lung per-fusion scans. Two series of images were registered using a visual method and the methods of different numbers and combinations of the external markers respectively based on Pinnacle~3 planning treatment system. After regis-tration , space coordinates of the 9 external markers were recorded respectively. The accuracy of registration was assessed using the absolute differences value of the 9 external markers coordinates between two series of images after registration. Results After registration using 9 external markers, the error in the left-right direction was the greatest, (1. 92 ±1.56 ) mm. Compared with that of using 9 external markers, there were statistical differ-ences using the visual method,2 external markers,3 external markers,4 external markers ( P < 0. 05 ), and there was no statistical difference using 5 external makers,6 external markers,7 external markers,8 external markers (P =0.081,0.061,0. 854,0. 860, respectively). Comparing the registration methods based on the middle thoracic external markers with the registration methods based on the pectus external markers using 4 ex-temal markers,5 external markers,6 external markers,there was no statistical difference between two methods and between the former and 9 external markers ( P =0.395,0. 110, respectively), and there was statistical difference between the latter and 9 external markers ( P = 0. 010). There was no statistical difference in the three registrations using 5 external markers ( P =0. 613,0. 26,0. 531 ,respectively). Conclusion The method of 5 external markers distributing non-coplanar is an accurate, reproducible and simple registration method of CT-SPECT lung perfusion images. Choosing the middle thoracic external markers less influenced by respiratory movement is a better method. Key words: Carcinoma, non- small- cell lung; Radiotherapy; Tomography, emission-computed, single-photon; Medical image registration

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.