Abstract
PurposeThe purpose of this paper is to present a methodology for estimating scheduled and manual override heating events and heating settings from indoor air temperature and gas use measurements in UK homes.Design/methodology/approachLiving room air temperature and gas use data were measured in ten UK homes built to low energy standards. The temperature measurements are used to establish whether the central heating system is turned on or off and to estimate the heating setpoint used. The estimated heating periods are verified using the homes' average daily gas consumption profiles.FindingsUsing this method, the average number of heating periods per day was 2.2 (SD = 0.8) on weekdays and 2.7 (SD = 0.5) on weekends. The weekday mean heating duration was 8.8 h and for weekends, it was 9.8 h. Manual overrides of the settings occurred in all the dwellings and added an average of 2.4 h and 1.5 h to the heating duration on weekdays and weekends respectively. The mean estimated setpoint temperatures were 21.2 and 21.4°C on weekdays and weekends respectively.Research limitations/implicationsManual overrides of heating behaviours have only previously been assessed by questionnaire survey. This paper demonstrates an alternative method to identifying these manual override events and responds to a key gap in the current body of research that little is currently reported on the frequency and duration of manual heating overrides in UK homes.Practical implicationsThe results could be used to better inform the assumptions of space heating behaviour used in energy models in order to more accurately predict the space heating energy demands of dwellings.Originality/valueManual overrides of heating behaviours have only previously been assessed by questionnaire survey. This paper demonstrates an alternative method to identifying these manual override events and responds to a key gap in the current body of research that little is currently reported on the frequency and duration of manual heating overrides in UK homes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Building Pathology and Adaptation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.