Abstract

The low-dose-rate brachytherapy technique has proven suitable for the management of prostate cancer. However, published data generally report the clinical outcome and the minimum peripheral dose (mPD) to the target volume and not the actual dose distribution in patients. To this end, modern guidelines recommend the use of specific dose and volume indices describing dose distribution throughout the target. The introduction of a method, based on the standard linear quadratic model and Poisson statistics, entitled the F-factor allows the TCP from different DVHs to be calculated, by using the TCP from a uniform dose distribution as the reference. The F-factor sensitivity against radiobiological parameters and influence of the DVH were evaluated. We applied the F-formula on the post-plan DVHs of 58 patients treated with 125I permanent seed implant brachytherapy for localized prostate cancer. F shows a strong correlation with dosimetric parameters already reported as significant predictors of the biochemical outcome.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.