Abstract
Abstract A laser interferometric method of detecting holidays in and evaluating the corrosion protection of epoxy primer or other coatings was tested in the well known system Zn/ZnSO4/Zn. An electrochemical potential in the general range of corrosion couple values was applied, first to uncoated electrodes, then to coated anodes with measured, prepared holidays. The method is shown to give easily interpretable, visually obvious qualitative results. General methods of calculating good relative values and less accurate true values of corrosion currents are evolved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.