Abstract
This paper presents a new technique for continuously calibrating the sensitivity of a current measurement microsystem based on a Hall magnetic field sensor. An integrated reference coil generates a magnetic field for calibration. Using a variant of the chopper modulation, the spinning current technique, combined with a second modulation of the reference signal, the sensitivity of the complete system is continuously measured without interrupting normal operation. Modulation and demodulation schemes allowing the joint processing of both external and reference magnetic fields are proposed. Additional techniques for extracting the very low reference signal are presented. The implementation of the microsystem is then discussed. Finally, measurements validate the calibration principle. A thermal drift lower than 50 ppm/degC is achieved. This is 6-10 times less than in state-of-the-art implementations. Furthermore, the calibration technique also compensates drifts due to mechanical stresses and ageing
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.