Abstract
A general correlation for heat transfer during film boiling in tubes is presented. It is based on the two-step model. It has been verified with data for nine fluids flowing up in tubes. The fluids include water, cryogens, refrigerants, and chemicals. The range of data includes pressures from 1 to 215 bar, reduced pressures from 0.0046 to 0.97, mass velocities from 4 to 5,176 kg/m² s, tube diameters from 1.1 to 24.3 mm, and qualities from 0.1 to 2.4. The 546 data points are predicted with a mean deviation of 15.2%. Deviation is defined as the difference between the measured and predicted heat transfer coefficients divided by the measured heat transfer coefficient, the heat transfer coefficients being based on the saturation temperature. Three other well-known correlations are also compared to the same data and found to have much larger deviations. The correlation is also compared with a limited amount of data from horizontal tubes; the results are encouraging.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.