Abstract

BackgroundThe convolution approach to thyroid time-activity curve (TAC) data fitting with a gamma distribution convolution (GDC) TAC model following bolus intravenous injection is presented and applied to 99mTc-MIBI data. The GDC model is a convolution of two gamma distribution functions that simultaneously models the distribution and washout kinetics of the radiotracer.The GDC model was fitted to thyroid region of interest (ROI) TAC data from 1 min per frame 99mTc-MIBI image series for 90 min; GDC models were generated for three patients having left and right thyroid lobe and total thyroid ROIs, and were contrasted with washout-only models, i.e., less complete models. GDC model accuracy was tested using 10 Monte Carlo simulations for each clinical ROI.ResultsThe nine clinical GDC models, obtained from least counting error of counting, exhibited corrected (for 6 parameters) fit errors ranging from 0.998% to 1.82%. The range of all thyroid mean residence times (MRTs) was 212 to 699 min, which from noise injected simulations of each case had an average coefficient of variation of 0.7% and a not statistically significant accuracy error of 0.5% (p = 0.5, 2-sample paired t test). The slowest MRT value (699 min) was from a single thyroid lobe with a tissue diagnosed parathyroid adenoma also seen on scanning as retained marker. The two total thyroid ROIs without substantial pathology had MRT values of 278 and 350 min overlapping a published 99mTc-MIBI thyroid MRT value. One combined value and four unrelated washout-only models were tested and exhibited R-squared values for MRT with the GDC, i.e., a more complete concentration model, ranging from 0.0183 to 0.9395.ConclusionsThe GDC models had a small enough TAC noise-image misregistration (0.8%) that they have a plausible use as simulations of thyroid activity for querying performance of other models such as washout models, for altered ROI size, noise, administered dose, and image framing rates. Indeed, of the four washout-only models tested, no single model approached the apparent accuracy of the GDC model using only 90 min of data. Ninety minutes is a long gamma-camera acquisition time for a patient, but a short a time for most kinetic models. Consequently, the results should be regarded as preliminary.

Highlights

  • The convolution approach to thyroid time-activity curve (TAC) data fitting with a gamma distribution convolution (GDC) time-activity curves (TACs) model following bolus intravenous injection is presented and applied to 99mTc-MIBI data

  • Several 99mTc-MIBI image acquisition protocols and analysis techniques have been devised over the last quarter century to aid in the detection of abnormal thyroid and parathyroid tissue, these include dual-phase scintigraphy [8], factor analysis of a dynamic scan [9], and time-activity curve (TAC) analysis of a dynamic scan [10]

  • We aim to demonstrate that following a peripheral intravenous bolus injection, the thyroid has a TAC that can be modelled accurately using the closed form convolution of two gamma distribution (GD) functions

Read more

Summary

Introduction

The convolution approach to thyroid time-activity curve (TAC) data fitting with a gamma distribution convolution (GDC) TAC model following bolus intravenous injection is presented and applied to 99mTc-MIBI data. Several 99mTc-MIBI image acquisition protocols and analysis techniques have been devised over the last quarter century to aid in the detection of abnormal thyroid and parathyroid tissue, these include dual-phase scintigraphy [8], factor analysis of a dynamic scan [9], and time-activity curve (TAC) analysis of a dynamic scan [10]. TAC analysis provides a means of differentiating between normal and abnormal tissues by comparing of radiotracer uptake and washout in different regions of interest (ROIs). Pharmacokinetic parameters, such as the tracer mean residence time (MRT) and elimination half-life can be used to quantify and characterize disease states, which may aid in the diagnosis of thyroid and parathyroid disease

Objectives
Methods
Results
Discussion
Conclusion