Abstract

BackgroundThe insulated isothermal PCR (iiPCR) technology enables consistent PCR amplification and detection in a simple heating device. A pan-dengue virus (DENV) RT-iiPCR, targeting the 5’ untranslated region, was validated previously on the semi-automated POCKIT combo system (involving separate devices for nucleic acid extraction and PCR amplification/detection) to offer performance comparable to a laboratory real-time PCR. Working on the same technologies, a compact automated sample-in-answer-out system (POCKIT Central Nucleic Acid Analyser) has been available commercially for iiPCR, minimizing human error risks and allowing easy molecular bio-detection near points of need. Here, we evaluated the analytical and clinical performance of the pan-DENV RT-iiPCR on the fully automated system by comparison to those on the semi-automated system.Methodology/Principal findingsTesting sera containing serial diluted DENV-1, -2, -3, or -4 cell culture stock, the pan-DENV RT-iiPCR system had similar 100% detection endpoints on the two systems; i.e. at 1, 10, 1 and 10 PFU/ml, respectively, on the fully automated system, and at 10, 1, 10 and 10 PFU/ml, respectively, on the semi-automated system. Furthermore, both fully automated and semi-automated PCR system can detect all four DENV serotypes in mosquitos. Clinical performance of the reagent on the two systems was evaluated by testing 60 human serum samples. Both systems detected the same 40 samples (ten DENV-1, -2, -3, and -4 positive each) and did not detect the other 20; 100% agreement (κ = 1) was found between the two systems.Conclusions/SignificanceWith performance comparable to a previously validated system, the fully-automated PCR system allows applications of the pan-DENV reagent as a useful tool near points of need to facilitate easy, fast and effective detection of dengue virus and help mitigate versatile public health challenges in the control and management of dengue disease.

Highlights

  • Dengue virus (DENV), a member of the genus Flavivirus in the family Flaviviridae, causes dengue in humans

  • We evaluated the performance of the pan-dengue virus (DENV) RT-insulated isothermal PCR (iiPCR) reagent on the POCKIT Central for sensitive and specific detection of DENV1-4 serotypes in human serums and mosquitos

  • The results indicated that performances of the pan-DENV RT-iiPCR on the two PCR systems were comparable

Read more

Summary

Introduction

Dengue virus (DENV), a member of the genus Flavivirus in the family Flaviviridae, causes dengue in humans. For dengue disease control, it is important to extend DENV surveillance in the human and mosquito populations to near points of care (POC)/point of needs (PON), generating early alert signals to prevent and/or control DENV epidemics and reducing the spread of DENV infection [7]. The insulated isothermal PCR (iiPCR) technology enables consistent PCR amplification and detection in a simple heating device. A pan-dengue virus (DENV) RT-iiPCR, targeting the 5’ untranslated region, was validated previously on the semi-automated POCKIT combo system (involving separate devices for nucleic acid extraction and PCR amplification/detection) to offer performance comparable to a laboratory real-time PCR. Working on the same technologies, a compact automated sample-in-answer-out system (POCKIT Central Nucleic Acid Analyser) has been available commercially for iiPCR, minimizing human error risks and allowing easy molecular bio-detection near points of need. We evaluated the analytical and clinical performance of the pan-DENV RT-iiPCR on the fully automated system by comparison to those on the semi-automated system

Methods
Results
Conclusion