Abstract

A switched DC voltage three level NPC is proposed in this paper to eliminate capacitor balancing problems in conventional three-level neutral point clamped (NPC) inverter. The proposed configuration requires only one DC link with a voltage Vdc/2, where Vdc is the DC link voltage in a conventional NPC inverter. To get rated DC link voltage (Vdc), the voltage source is alternately connected in parallel to one of the two series capacitors using two switches and two diodes with device voltage rating of Vdc/2. The frequency at which the voltage source is switched is independent and will not affect the operation of NPC inverter. The switched voltage source in this configuration balances the capacitors automatically. The proposed configuration can also be used as a conventional two level inverter in lower modulation range, thereby increases the reliability of the drive system. A space vector based PWM scheme is used to verify this proposed topology.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call