Abstract
Due to the disadvantages of single calibration way and low efficiency of the dualchannel monopoles radar phase calibration method and single frequency calibration for one time, we propose a method of phase calibration based on the information plus channel group delay, by which we can deduce the phase of the whole frequency just through one single phase calibration with high efficiency. In this paper, we explain the reason for dual-channel monopoles radar, analyze the disadvantages of current calibration method and prove the feasibility of this phase calibration method based on group delay. By experiments, we testify that the calibration results by this method can satisfy the performance demands of the equipment. This method improves the calibration process and efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: DEStech Transactions on Computer Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.