Abstract
Single Particle Aerosol Mass Spectrometers (SPAMS) have been increasingly deployed for aerosol studies in Asia. To date, SPAMS is most often used to provide unscaled information for both the size and chemical composition of individual particles. The instrument's lack of accuracy is primarily due to only a fraction of particles being detected after collection, and the instrumental sensitivity is un-calibrated for various chemical species in mixed ambient aerosols. During a campaign from January to April 2013 at a coastal site in Hong Kong, the particle number information and ion intensity of major PM2.5 components collected by SPAMS were scaled by comparing with collocated bulk PM2.5 measurements of hourly or higher resolution. The bulk measurements include PM2.5 mass by a SHARP 5030 Monitor, major ions by a Monitor for Aerosols & Gases in ambient Air (MARGA), and organic carbon (OC) and elemental carbon (EC) by a Sunset OCEC analyzer. During the data processing, both transmission efficiency (scaled with the Scanning Mobility Particle Sizer) and hit efficiency conversion were considered, and component ion intensities quantified as peak area (PA) and relative peak area (RPA) were analyzed to track the performance. The comparison between the scaled particle mass assuming a particle density of 1.9 g cm−3 from SPAMS and PM2.5 concentration showed good correlation (R2 = 0.81) with a slope of 0.814 ± 0.004. Regression analysis results suggest an improved scaling performance using RPA compared with PA for most of the major PM2.5 components, including sulfate, nitrate, potassium, ammonium, OC and EC. Thus, we recommend preferentially scaling these species using the RPA. For periods of high K+ concentrations (>1.5 μg m−3), under-estimation of K+ by SPAMS was observed due to exceeding the dynamic range of the acquisition board. When only applying the hit efficiency correction, data for sulfate, nitrate, ammonium, potassium and OC were in reasonably good correlation (R2 = 0.56–0.79) with the bulk measurements, suggesting semi-quantified data by the hit efficiency correction can be utilized when transmission efficiency correction is not available. More inter-comparisons of this type are needed to assess the inter-instrument variability among different SPAMS instruments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.