Abstract
Radon concentration was estimated using an accumulation chamber equipped with AlphaGUARD radon monitor. It varies from 12.6±1.20 to 363±19.3Bqm-3 with a mean value of 180±11.2Bqm-3. A good correlation between radium content and radon concentrations was obtained of R=0.754, which suggests that radium is the main reason of releasing radon to the atmosphere. Radon emanation coefficient and exhalation rate were also calculated. Furthermore, the radiation dose rate was measured with a high-pressure ionization chamber detector. The radiation dose rate was strongly correlated with the radon concentration and exhalation rate of R=0.85 and 0.63. The obtained results support our idea that the radiation dose rate can be a good indicator to the radon level in the atmosphere. In addition, the dependence of radon concentration on the water content was discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.