Abstract

This paper presents a method for designing residual generators using minimum-order functional observers to detect actuator and component faults in time-delay systems. Existence conditions of the residual generators and functional observers are first derived, and then based on a parametric approach to the solution of a generalized Sylvester matrix equation, we develop systematic procedures for designing minimum-order functional observers to detect faults in the system. The advantages of having minimum-order observers are obvious from the economical and practical points of view as cost saving and simplicity can be achieved, particularly when dealing with high-order complex systems. Extensive numerical examples are given to illustrate the proposed fault detection scheme. In all the numerical examples, we design minimum-order residual generators and functional observers to detect faults in the system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.