Abstract

paper-based analytical device (μPAD) for in situ rapid colorimetric detection of microorganisms in environmental water samples. We fabricated the μPAD with the wax printing method at curing conditions of 100°C for 7 seconds. For quick bacterial detection, we modified the catalase test with Fenton’s reaction as a colorimetric biochemical reaction. This modified catalase test provided a color indicator according to the concentration of Escherichia coli (E. coli, XL-1 Blue strain). All of the image data from the detection chamber of the μPAD was analyzed at the precision of 300 pixels for each color space component (i.e., hue, saturation, and value in HSV color). In addition, environmental samples were tested with our μPAD, and the data were fitted in the range of colorimetric reference chart for E. coli sample testing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.