Abstract

BackgroundTo compare the dosimetric, normal tissue complication probability (NTCP), secondary cancer complication probabilities (SCCP), and excess absolute risk (EAR) differences of volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for left-sided breast cancer after mastectomy.Methods and materialsThirty patients with left-sided breast cancer treated with post-mastectomy radiation therapy (PMRT) were randomly enrolled in this study. Both IMRT and VMAT treatment plans were created for each patient. Planning target volume (PTV) doses for the chest wall and internal mammary nodes, PTV1, and PTV of the supraclavicular nodes, PTV2, of 50 Gy were prescribed in 25 fractions. The plans were evaluated based on PTV1 and PTV2 coverage, homogeneity index (HI), conformity index, conformity number (CN), dose to organs at risk, NTCP, SCCP, EAR, number of monitors units, and beam delivery time.ResultsVMAT resulted in more homogeneous chest wall coverage than did IMRT. The percent volume of PTV1 that received the prescribed dose of VMRT and IMRT was 95.9 ± 1.2% and 94.5 ± 1.6%, respectively (p < 0.001). The HI was 0.11 ± 0.01 for VMAT and 0.12 ± 0.02 for IMRT, respectively (p = 0.001). The VMAT plan had better conformity (CN: 0.84 ± 0.02 vs. 0.78 ± 0.04, p < 0.001) in PTV compared with IMRT. As opposed to IMRT plans, VMAT delivered a lower mean dose to the ipsilateral lung (11.5 Gy vs 12.6 Gy) and heart (5.2 Gy vs 6.0 Gy) and significantly reduced the V5, V10, V20, V30, and V40 of the ipsilateral lung and heart; only the differences in V5 of the ipsilateral lung did not reach statistical significance (p = 0.409). Although the volume of the ipsilateral lung and heart encompassed by the 2.5 Gy isodose line (V2.5) was increased by 6.7% and 7.7% (p < 0.001, p = 0.002), the NTCP was decreased by 0.8% and 0.6%, and SCCP and EAR were decreased by 1.9% and 0.1% for the ipsilateral lung. No significant differences were observed in the contralateral lung/breast V2.5, V5, V10, V20, mean dose, SCCP, and EAR. Finally, VMAT reduced the number of monitor units by 31.5% and the treatment time by 71.4%, as compared with IMRT.ConclusionsCompared with IMRT, VMAT is the optimal technique for PMRT patients with left-sided breast cancer due to better target coverage, a lower dose delivered, NTCP, SCCP, and EAR to the ipsilateral lung and heart, similar doses delivered to the contralateral lung and breast, fewer monitor units and a shorter delivery time.

Highlights

  • To compare the dosimetric, normal tissue complication probability (NTCP), secondary cancer complication probabilities (SCCP), and excess absolute risk (EAR) differences of volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for left-sided breast cancer after mastectomy

  • The volume of the ipsilateral lung and heart encompassed by the 2.5 Gy isodose line ­(V2.5) was increased by 6.7% and 7.7% (p < 0.001, p = 0.002), the NTCP was decreased by 0.8% and 0.6%, and SCCP and EAR were decreased by 1.9% and 0.1% for the ipsilateral lung

  • Compared with IMRT, VMAT is the optimal technique for post-mastectomy radiotherapy (PMRT) patients with left-sided breast cancer due to better target coverage, a lower dose delivered, NTCP, SCCP, and EAR to the ipsilateral lung and heart, similar doses delivered to the contralateral lung and breast, fewer monitor units and a shorter delivery time

Read more

Summary

Introduction

Normal tissue complication probability (NTCP), secondary cancer complication probabilities (SCCP), and excess absolute risk (EAR) differences of volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for left-sided breast cancer after mastectomy. Adjuvant post-mastectomy radiotherapy (PMRT) has been shown to effectively reduce locoregional failure and mortality in breast cancer [4, 5]. PMRT often involves regional lymph nodes, including for instance internal mammary nodes (IMN) and supraclavicular nodes (SCN). The covering of these lymph node regions often results in larger irradiation fields and volumes. It is especially important to adopt an appropriate radiotherapy technology (RT) that ensures sufficient irradiation dose coverage to the target area and reduces the dose to the surrounding normal tissue as much as possible

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.