This paper presents a new digital background calibration algorithm for pipelined analog-to-digital converters (ADCs). Background calibration can extract calibration data without interrupting ADCs normal conversion operation. Digital calibration can relax the design difficulty of analog circuits of ADCs, and gains the improvement of technology scaled down. This algorithm provides a method to effectively estimate the nonlinearity of op amp, and calibrates it in digital domain without any additional analog circuit. Simulation results show that the ENOB can be improved from 6.3b to 10.67b by the proposed algorithm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.