Abstract

The segmented ringed gamma scanning (SRGS) technique represents an advancement in segmented gamma scanning (SGS) technology used for detecting the density of radioactive waste drums, offering enhanced measurement accuracy. However, significant occur errors in the reconstruction of matrix densities due to the non-uniform distribution of density in radioactive waste and the conical beam emitted from the transmission source collimator. This paper proposes a density correction method based on dichotomy to address this issue. The efficacy of this method was verified through both simulations and experiments on a sample containing five different materials, utilizing 137Cs and 60Co for transmission and emission measurements, respectively. The experimental results demonstrate that the errors in the corrected matrix densities are reduced, falling within a margin of 16.8%. Additionally, the corrected reconstruction error of the activity is approximately 25% of the uncorrected results.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call