Abstract
In the present paper, we show a rare case of the large abdominal wall defect and enterocutaneous fistulas after the tension free repair using prostheses for incisional hernia. The patient, a 70-year-old man, had a history of a hemicolectomy for a perforating colon cancer, complicated by a large incisional hernia that was closed primarily but recurred. Three years later, the hernia was repaired at the time of a second colectomy using a Composix Kugel Patch. His course was complicated by a chronic postoperative wound infection with eventual development of enterocutaneous fistulas. The patient was successfully treated with extirpation of the prosthesis, resection of the fistulized bowel, and placement of a tensor fasciae latae myocutaneous flap. Enterocutaneous fistulas are a known complication of incisional hernia repairs using prostheses. Additional clinical data are required to confirm the safety and efficacy of this procedure as it becomes more widely adopted. Extirpation of the prosthesis should be performed without delay to prevent serious complications. Reconstruction with a tensor fasciae latae myocutaneous flap was useful for the large abdominal wall defect.