Abstract

In this paper, an integrated data-driven fault-tolerant control (FTC) design scheme is proposed under the configuration of the Youla parameterization for multiple-input multiple-output (MIMO) systems. With unknown system model parameters, the canonical form identification technique is first applied to design the residual observer in fault-free case. In faulty case, with online tuning of the Youla parameters based on the system data via the gradient-based algorithm, the fault influence is attenuated with system performance optimization. In addition, to improve the robustness of the residual generator to a class of system deviations, a novel adaptive scheme is proposed for the residual generator to prevent its over-activation. Simulation results of a two-tank flow system demonstrate the optimized performance and effect of the proposed FTC scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.