Abstract

Abstract A simple and coumarin-based fluorescence probe has been designed and synthesized with silyl group as recognition group of fluoride ions (F−) in this study. The results showed that the fluorescence intensity of the probe displayed prominent enhancement with addition of F− at 445 nm with incubation of 1 min. There was an excellent linear relationship between fluorescence intensity and fluoride concentration from 0 to 30 μM (0~0.57 ppm), which offered the important condition for the quantitative analysis. In addition, the highly selective response to fluorion, the low detection limit with 28 nM (0.532 ppb), low toxicity and bioimaging afforded an advantage for practical application and detecting fluoride in biological systerms.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call