Abstract

Due to its ideal physical properties, fluorine-18 turns out to be a key radionuclide for positron emission tomography (PET) imaging, for both preclinical and clinical applications. However, usual biomolecules radiofluorination procedures require the formation of covalent bonds with fluorinated prosthetic groups. This drawback makes radiofluorination impractical for routine radiolabeling, gallium-68 appearing to be much more convenient for the labeling of chelator-bearing PET probes. In response to this limitation, a recent expansion of the 18F chemical toolbox gave aluminum [18F]fluoride chemistry a real prominence since the late 2000s. This approach is based on the formation of an [18F][AlF]2+ cation, complexed with a 9-membered cyclic chelator such as NOTA, NODA or their analogs. Allowing a one-step radiofluorination in an aqueous medium, this technique combines fluorine-18 and non-covalent radiolabeling with the advantage of being very easy to implement. Since its first reports, [18F]AlF radiolabeling approach has been applied to a wide variety of potential PET imaging vectors, whether of peptidic, proteic, or small molecule structure. Most of these [18F]AlF-labeled tracers showed promising preclinical results and have reached the clinical evaluation stage for some of them. The aim of this report is to provide a comprehensive overview of [18F]AlF labeling applications through a description of the various [18F]AlF-labeled conjugates, from their radiosynthesis to their evaluation as PET imaging agents.

Highlights

  • 68 Ga in positron emission tomography (PET) Imaging and Radiolabeling Pros and ConsPositron emission tomography (PET) is currently an essential medical imaging technique in the diagnosis of cancer diseases, therapeutic efficacy monitoring, preclinical research and general molecular imaging24, x [1]

  • The purpose of this review is to provide a comprehensive overview of the use of the [18F]aluminum monofluoride (AlF)

  • Among the different radiofluorination methods available to label potential PET imaging agents, the non-covalent approach using aluminum [18 F]fluoride has been widely exemplified since its first report in 2009

Read more

Summary

A Comprehensive Review of Non-Covalent

Radiofluorination Approaches Using Aluminum [18F]fluoride: Will [18F]AlF Replace 68Ga for Metal. Cyril Fersing 1,2, * , Ahlem Bouhlel 3,4 , Christophe Cantelli 1,5 , Philippe Garrigue 3,4,6 , Vincent Lisowski 5 and Benjamin Guillet 3,4,6. Institut de Recherche en Cancérologie de Montpellier (IRCM), University of Montpellier, INSERM U1194, Montpellier Cancer Institute (ICM), 34298 Montpellier, France. Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298 Montpellier CEDEX 5, France. Centre de recherche en CardioVasculaire et Nutrition (C2VN), Aix-Marseille University, INSERM 1263, INRA 1260, 13385 Marseille, France. Institut des Biomolécules Max Mousseron, UMR 5247, CNRS, Université de Montpellier, ENSCM, UFR des Sciences Pharmaceutiques et Biologiques, 34093 Montpellier CEDEX, France

68 Ga in PET Imaging and Radiolabeling
The Place of 18 F in Routine Radiolabeling
Examples of pentadentate or hexadentate bifunctionnal chelators to radiolabel
Process
Chemical
11. Chemical
13. Chemical
15. Schematic structures of 18F-radiolabeled
Current
Conclusions
68 Ga-DOTATOC
18 F-labeled silicon-based fluoride acceptors
Findings
18 F-AlF-NOTA-PRGD
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call