Abstract

A numerical particulate matter (PM) measurement model is developed to characterize and evaluate PM sampling methods. Simulations are conducted using the model to evaluate currently widely used PM samplers, including Federal Reference Method (FRM) samplers. The simulations show that current PM samplers are very vulnerable to both changes in measurement target (i.e., natural variability of particle size distribution) and the sampler’s design, manufacturing, and operating conditions, potentially resulting in significant errors in the monitoring data. The numerical model is used in conjunction with two types of commercially available PM monitoring devices to form a Comprehensive Particulate Matter Monitoring System (CPMMS). The first type of device can be any mass-based PM monitor with a well-defined sampling efficiency curve. The second type of device is one capable of measuring particle size distribution with a reasonably good relative accuracy between size categories but not necessarily accurate in measuring absolute mass concentrations. This study shows that CPMMS can produce much higher quality PM monitoring data than the current PM samplers under the same conditions. In addition, unlike past and current PM monitoring data such as total suspended particulates, coarse PM (PM10), fine PM (PM2.5), etc., the CPMMS monitoring data will survive changes in PM regulatory definition. A new concept, dosimetry-based PM metrics and standards, is proposed to define ambient PM level based on the deposition fraction of particles in the human respiratory tract. The dosimetry-based PM metrics is more meaningful because it correlates the ambient PM level with the portion that can be deposited in the respiratory tract without an arbitrary cutoff particle diameter. CPMMS makes dosimetry-based PM metrics and standards feasible.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call