Abstract

A 71-year old man with previous thoracic aneurysm endovascular repair and endovascular abdominal aneurysm repair presented with simultaneous type III endoleak from the thoracic components and type Ia endoleak from migration of the abdominal endograft, leading to enlargement of both aneurysms. A custom-made reverse tapered Relay NBS thoracic endograft was used to bridge the thoracic stent grafts. While a low-flow type III endoleak persisted in the immediate postoperative phase, because of incomplete apposition of the new stent graft, further deployment of its nitinol skeleton resulted in resolution of the endoleak at 1-week follow-up. The abdominal aneurysm enlargement was corrected via excision of the central segment of the abdominal endograft, preservation of the distal main body and limbs, and interposition of a short Dacron tube graft.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.