Abstract
This study evaluated a new light-emitting diode (LED-S) photic stimulator and compared skin electroretinogram (ERG) responses obtained to those evoked by the Grass Instrument stimulator (GP-S). Two sub-studies were combined to evaluate the difference in responses resulting from the LED-S and GP-S stimuli. The first was a photometry study that matched the LED-S stimuli to the GP-S. In the second study, electroretinograms (ERGs) were recorded under scotopic and photopic conditions using stimuli each stimulator. The stimuli were matched photometrically to measurements obtained from the photometer located 30cm in front of the stimulators. In addition, the ERG responses were recorded from the LED stimulator when photometrically matched to the GP-S blue stimulus presented through a ganzfeld. The amplitudes and time peaks of the resulting ERG a- and b-waves were then measured and compared using paired T-tests. Study 1: The LED-S was matched to the GP-S at various intensity settings measured 30cm away from the stimulator. Measurement through a ganzfeld full-field stimulator (GFFS) demonstrated that the GP-S had a significant hot spot centrally. Study 2: Photometrically matched ERGs evoked by both stimulators while employing the direct head-on measurements demonstrated multiple similarities. Similarities included component morphology, amplitude and implicit time across the two stimulators, excluding the rod-driven stimulus (GP-S setting employing a blue filter). Differences between the rod-driven ERGs evoked by the GP-S and LED-S while employing head-on photometric measurements were due to the significant difference in intensities between the two stimulators. The GP-S and LED-S evoked similar rod-driven ERG responses when they were matched using the GFFS photometrically matched intensities protocol. A hand-held stimulator is essential when recording ERG's in the practice of paediatric visual electrophysiology. The LED-S can match the GP-S stimulus intensities, making it a potential replacement for the GP-S. In addition, the LED-S has uniform intensity across the surface of the device compared to the GP-S, is silent for standard stimuli and can generate prolonged duration stimuli for the recording of on-off ERGs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Documenta ophthalmologica. Advances in ophthalmology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.